The Effect of Iranian Evaporative Cold Vest on Physiological Indices in Hot and Dry Climate in a Climatic Chamber

Authors

Abstract

Background: Heat stress is a threat for health and safety in workplaces. The aim of this study was to examine the cooling ability of the Iranian evaporative vest in hot and dry conditions in a climatic chamber.


Method: This interventional study was conducted on 12 male students in 2013. Heat strain score index, skin temperature, oral temperature and heartbeat in two phases of with and without wearing cold vest were measured in two intensity different activities on a treadmill in a climatic chamber (mean temperature 38.8ºC, relative humidity 32.9% and WBGT 29.9ºC). Data were analyzed using t-test and repeated measures test.


Results: In two trials with and without wearing the evaporative cooling vest, the skin mean temperature differed significantly but heat strain score, heartbeat rate and oral temperature in both activities did not show a significant difference.


Conclusion: The results showed that Iranian evaporative cooling vest is effective in reducing skin temperature, in light and moderate activities, in hot and dry conditions; but it has a little effect on oral temperature, heart rate and heat strain score index.

Keywords


1. Clapp AJ, Bishop PA, Muir I, Walker JL. Rapid cooling techniques in joggers experiencing heat strain. J Sci Med Sport. 2001 Jun;4(2):160-7. 2. Cotter JD, Sleivert GG, Roberts WS, Febbraio MA. Effect of pre-cooling, with and without thigh cooling, on strain and endurance exercise performance in the heat. Comp Biochem Physiol A Mol Integr Physiol. 2001 Apr;128(4):667-77. 3. Carter JM, Rayson MP, Wilkinson DM, Richmond V, Blacker S. Strategies to combat heat strain during and after firefighting. Journal of Thermal Biology. 2007;32(2):109-16. 4. Furtado AL, Craig BN, Chard JT, Zaloom VA, Chu HW. Cooling suits, physiological response, and task performance in hot environments for the power industry. Int J Occup Saf Ergon. 2007;13(3):227-39. 5. Dehghan H, Parvari R, Habibi E, Maracy MR. Effect of fabric stuff of work clothing on the physiological strain index at hot conditions in the climatic chamber. Int J Env Health Eng 2014; 3:14. 6. Dehghan H, Gharebaie S, Maeki B. Accessing the impact of three types of Iranian cooling vests on heat strain index in hot/ dry weather conditions.[dissertation] Isfahan: Isfahan University of Medical Sciences; 2015. 7. Xu X, Gonzalez J. Determination of the cooling capacity for body ventilation system. Eur J Appl Physiol. 2011 Dec;111(12):3155-60. 8. Chi YC, Chin YC, Dimoski D, Kroll R, Low ACH. Water Cooling Vest. Final Report for Team 14 of ME450; 2008. [cited 2012 Sep 28] Available from: https://deepblue.lib.umich.edu/bitstream/handle/2027.42/61923/me450fall2008finalreport-team14-coolingvest.pdf?sequence=1 9. Angelo SD, Lauwers W. The Cooling Vest-Evaporative Cooling. Worcester Polytechnic Institute; 2009. [cited 2013 Jul 28 ] Available from: https://www.wpi.edu/Pubs/E-project/Available/E-project-043009-013901/unrestricted/Final_Cooling_Vest[1].pdf 10. Hornery DJ, Papalia S, Mujika I, Hahn A. Physiological and performance benefits of halftime cooling. J Sci Med Sport. 2005 Mar;8(1):15-25. 11. Hadid A, Yanovich R, Erlich T, Khomenok G, Moran DS. Effect of a personal ambient ventilation system on physiological strain during heat stress wearing a ballistic vest. Eur J Appl Physiol. 2008 Sep;104(2):311-9. 12. Selkirk GA, McLellan TM, Wong J. Active versus passive cooling during work in warm environments while wearing firefighting protective clothing. J Occup Environ Hyg. 2004 Aug;1(8):521-31. 13. Bennett BL, Hagan RD, Huey KA, Minson C, Cain D. Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble. Eur J Appl Physiol Occup Physiol. 1995;70(4):322-8. 14. Gao C, Kuklane K, Holmér I. Cooling vests with phase change materials: the effects of melting temperature on heat strain alleviation in an extremely hot environment. Eur J Appl Physiol. 2011 Jun;111(6):1207-16. 15. Branson DH, Cao H, Jin B, Peksoz S, Farr C, Ashdown S. Fit analysis of liquid cooled vest prototypes using 3D body scanning technology. Journal of Textile and Apparel. 2005;3 (4):1-13. 16. Karkalic RM, Jovanović DB, Radakovic SS, Rajic DS, Petrovic BV, Ivankovic ND, et al. The influence of the passive evaporative cooling vest on a chemical industry workers physiological strain level in hot conditions. Hemijska industrija. 2015;69(3): 587-94. 17. Sarkar S, Kothari VK. Cooling garments—a review. Indian Journal of Fibre & Textile Research. 2014;39(4):450-8. 18. Kim JH, Coca A, Williams WJ, Roberge RJ. Effects of liquid cooling garments on recovery and performance time in individuals performing strenuous work wearing a firefighter ensemble. J Occup Environ Hyg. 2011 Jul;8(7):409-16.